AESMR reports for Victorian sites

FireSeq prepares each Victorian site’s annual essential safety measures report from its measures register and your service records, laid out like the approved form, with the maintenance record attached. You check it, and the owner signs it.

An AESMR from FireSeq: the first page with the building details and the form's sections, and the attached maintenance record with each measure's visits, results and open defects
A draft AESMR for a sample site, part way through its year.

What the AESMR is

In Victoria the owner of a building with essential safety measures must make an annual essential safety measures report, in the 28 days before the anniversary of its occupancy permit or maintenance determination. The owner signs it and keeps it with the building’s records.

Most of what goes in it comes from the fire contractor’s records, so FireSeq prepares it from yours.

What FireSeq fills in

  • The building, address, class and owner, the 12 months the report covers and the 28 days in which to make it.
  • Each section of the approved form (version 1.0, September 2019), published by the Building and Plumbing Commission (formerly the VBA), in its order.
  • Measures maintained to AS 1851-2012 in place of the specified standard.
  • Who maintained what: your company first, then other contractors and the owner, each with the measures they look after.
  • The owner’s statement, with Owner or Agent to tick, ready to sign.
  • An attached maintenance record: every visit for each measure with pass, fail and no-test counts, the defects still open, and each technician with their licence number.

What you set up once

  • The site’s measures register, from its occupancy permit or maintenance determination. The standard measures can be added in one go.
  • Who maintains each measure, so the ones the owner or another contractor looks after are not counted as gaps.
  • The site’s routines. A measure with no routine behind it is flagged on the register.

Where to find it

In the office app, on the site’s Measures tab, or on a task’s Documents tab with the service and defect reports. It is offered for Victorian sites only.

Open it at any time of the year: a year still under way prints as a draft with the records to date. Save a copy and it is kept in the site’s documents, in the Compliance folder.

What stays with the owner

The owner, or their agent, checks and signs the report and keeps it. FireSeq does not lodge it anywhere.

Sites in NSW

NSW sites get the AFSS supporting pack instead: each measure on the fire safety schedule with its last assessment, the result or open defects, and who assessed it. The statement itself stays on the NSW form, signed by the owner and the accredited practitioner.

Requirements by state